vPad Products
Vision-Pad Technology™ uses an Android tablet to function as the display and control unit for our vPad series of electrical safety testing device. Click here to find out more about Vision Pad Technology™.
-
vPad-Rugged 2
- Designed for the Toughest Environments
- Built in Wireless Connectivity
- Automation, Data Transfer, and Service Manuals on Tablet – no need for a laptop or to carry physical documents
- Automation Apps (optional)
-
vPad-ES 2
- vPad‐ES 2 is the desktop version of the vPad‐Rugged 2 and is designed for users who do not require portability
- Automated and Manual Electrical Safety Testing per AAMI/ANSI ES-1, NFPA-99 2012, IEC 60601, and IEC 62353 standards
- Wireless Connectivity via Wi-Fi & Bluetooth
- Scalable via Apps
- Compatible with most CMMS systems
-
vPad-Mini
- Manual Electrical Safety Analyzer
-
vPad‐Mini™ enables Clinical and Field Service Engineers to quickly perform basic electrical safety checks on all types of medical equipment, ranging from beds to patient monitors with applied parts.
-
vPad-IN
- Built on the Vision-Pad platform to give you greater flexibility and scalability
- Wireless control of tests within incubator
- Changes to test can be made without disturbing heat environment
- Measures all parameters automatically following user defined protocols
- Results can be merged with Electrical Safety test data and imported into commonly used CMMS system
-
vPad-A1
- The only modular Vital Signs Simulator on the market
- Modules can be used together, independently, or in various combinations
- SpO2 and NIBP modules are compatible with all major manufacturers
- Integrated user customizable SpO2 R-Curves and NIBP Envelopes
- Control via Bluetooth or USB
-
vPad-O2
- Next generation SpO2 Tester
- Can be combined with vPad-PS & vPad-BP
- User programmable settings allow for easy on-site configuration to accommodate new models of SpO2 sensors.
-
vPad-PS
- Full 12-Lead ECG
- ECG Performance Testing
- Over 60 Arrhythmia selections
- Built-in Cardiac Output feature
- 2 Temperature Channels
- Respiration simulation rates from 10 to 150 bpm
- 2 Channel IBP (invasive blood pressure)
- Part of the vPad-A1 family so can be used in conjunction with vPad-O2 & vPad-BP
-
vPad-CO2
- Built on the Vision-Pad (vPad) platform
- Designed to test capnometers, patient monitors with capnography functionality, and that of respiratory gas analyzers
- Can be controlled and operated as part of Datrend’s vPad-A1 Multi-Parameter Patient Simulator, or it can run as a standalone unit with an optional 10” screen to carry out only capnography testing
- Can be used for waveform simulation for evaluating and testing of respiratory gas analyzers
- Comes in a portable ruggedized IP67 enclosure that is airtight and waterproof when closed, perfect for on-the-go professionals!
-
vPad-BP
- Compatible with all major industry manufacturers
- Field editable Envelopes allows for easy set up of new patient monitors
- Unlimited preset NIBP simulations
- Easy to navigate
- Auto Settings
- Control via Bluetooth or USB
- Test reports
- Field upgradeable
- Part of the vPad-A1 family
Electrical Safety Analyzers
-
vPad-Rugged 2
- Designed for the Toughest Environments
- Built in Wireless Connectivity
- Automation, Data Transfer, and Service Manuals on Tablet – no need for a laptop or to carry physical documents
- Automation Apps (optional)
-
vPad-ES 2
- vPad‐ES 2 is the desktop version of the vPad‐Rugged 2 and is designed for users who do not require portability
- Automated and Manual Electrical Safety Testing per AAMI/ANSI ES-1, NFPA-99 2012, IEC 60601, and IEC 62353 standards
- Wireless Connectivity via Wi-Fi & Bluetooth
- Scalable via Apps
- Compatible with most CMMS systems
-
vPad-Mini
- Manual Electrical Safety Analyzer
-
vPad‐Mini™ enables Clinical and Field Service Engineers to quickly perform basic electrical safety checks on all types of medical equipment, ranging from beds to patient monitors with applied parts.
Fetal & Neonatal Test Equipment
-
vPad-IN
- Built on the Vision-Pad platform to give you greater flexibility and scalability
- Wireless control of tests within incubator
- Changes to test can be made without disturbing heat environment
- Measures all parameters automatically following user defined protocols
- Results can be merged with Electrical Safety test data and imported into commonly used CMMS system
-
FMS-3
- Setting a new performance standard in Fetal/Maternal simulation
- Two direct Fetal ECG’s
- Five full Maternal ECG leads
- Four separate Fetal ECG tracings
- Three independent Fetal ultrasound channels with “triplets” capability
- Thirteen Fetal static ECG rates
- Fifteen trends of Fetal data representing real-life case studies
Infusion Device Analyzers
-
vPad-IV
- Field configurable between 1 – 6 channels
- Large Intuitive User Interface
- Simple Automatic Pass/Fail Testing
- Built-in Autosequence Editor
- Full-range class-leading accuracy from 0.1 – 3000 ml/hr
- Conforms to all IEC 60601-2-24 test requirements
-
Infutest Solo
- Single Channel, battery operated providing up to 30 hours of continuous operation
- Better than 1% accuracy on ALL pumps
Multi-Parameter Patient Simulator
-
vPad-A1
- The only modular Vital Signs Simulator on the market
- Modules can be used together, independently, or in various combinations
- SpO2 and NIBP modules are compatible with all major manufacturers
- Integrated user customizable SpO2 R-Curves and NIBP Envelopes
- Control via Bluetooth or USB
-
vPad-O2
- Next generation SpO2 Tester
- Can be combined with vPad-PS & vPad-BP
- User programmable settings allow for easy on-site configuration to accommodate new models of SpO2 sensors.
-
vPad-PS
- Full 12-Lead ECG
- ECG Performance Testing
- Over 60 Arrhythmia selections
- Built-in Cardiac Output feature
- 2 Temperature Channels
- Respiration simulation rates from 10 to 150 bpm
- 2 Channel IBP (invasive blood pressure)
- Part of the vPad-A1 family so can be used in conjunction with vPad-O2 & vPad-BP
-
vPad-CO2
- Built on the Vision-Pad (vPad) platform
- Designed to test capnometers, patient monitors with capnography functionality, and that of respiratory gas analyzers
- Can be controlled and operated as part of Datrend’s vPad-A1 Multi-Parameter Patient Simulator, or it can run as a standalone unit with an optional 10” screen to carry out only capnography testing
- Can be used for waveform simulation for evaluating and testing of respiratory gas analyzers
- Comes in a portable ruggedized IP67 enclosure that is airtight and waterproof when closed, perfect for on-the-go professionals!
-
vPad-BP
- Compatible with all major industry manufacturers
- Field editable Envelopes allows for easy set up of new patient monitors
- Unlimited preset NIBP simulations
- Easy to navigate
- Auto Settings
- Control via Bluetooth or USB
- Test reports
- Field upgradeable
- Part of the vPad-A1 family
-
AMPS-1
- 12 lead ECG simulation with 9 independent outputs for each signal lead
- ECG Performance Testing
- 52 Arrhythmia selections
- Temperature and Respiration Simulations
- Pacer simulations
-
Oxitest Plus7
- Exclusive Nellcor-Puritan Bennett sensor port, developed in cooperation with Nellcor®
- Easy adjustment of five preset oxygen saturation levels, six preset heart rates and four preset amplitudes
- Signal Artifact simulations, preset patient parameters, Alarm Testing and Report printing